Cleanrooms in the Pharma Industry: What You Should Know?

Cleanrooms are a critical component in the pharma and biotech industries. They ensure the quality and safety of products and protect them from contamination. In this blog, we will review the key requirements for cleanrooms, the reasons for the different grades according to European guidelines, ISO guidelines, and compare them. We will delve into the important parameters for air exchange and flow, bacterial levels, validation and re-validation, and the principles of filtration and laminar flow.

Cleanroom design requires a combination of many complex engineering principles, including the design of ventilation and air conditioning systems, the selection of appropriate materials and construction, the design of lighting systems, control and monitoring, management of the flow of people and materials, maintenance and cleaning, compliance with standards and regulations, and future flexibility. Ensuring compliance with all of these principles will help maintain a clean and safe environment in the pharmaceutical industry and other fields where a high level of cleanliness is required.

Clean rooms began to develop in the 1960s, with the aim of improving product quality and preventing contamination. Over time, the devices and technologies have improved and today they are an integral part of the industry.

Clean room requirements

Clean rooms are defined as areas where a certain level of cleanliness is maintained by controlling the amount of particles and bacteria in the air. In the pharmaceutical industry, these rooms are used for drug manufacturing, research and development, and packaging. The requirements for clean rooms vary depending on the use and the strict regulations on different products.

Design of ventilation and air conditioning (HVAC) systems:

High-Efficiency Particulate Air – HVAC systems are critical for maintaining appropriate levels of cleanliness, humidity, and temperature:

Air filtration: Using HEPA or (Ultra-Low Penetration Air) ULPA filters to capture small particles.

Laminar Airflow: Ensures unidirectional airflow to reduce the risk of contamination. The flow is straight from the filter to the work area where the sterile material is exposed.

Air Exchange: Design high air exchange rates to maintain low particulate levels.

HEPA Filter Operation

HEPA (High-Efficiency Particulate Air) filters are highly efficient filters that capture very small particles, including dust, pollen, spores, and smoke. They are designed to remove at least 99.97% of particles 0.3 microns in size and larger.

How does a HEPA filter work?

A HEPA filter consists of dense fibrous media arranged in parallel mats or layers. Contaminated air passes through the filter, and the particles are captured by various mechanisms:

Physical Filtration: Particles larger than the filter channels simply get stuck in the filter fibers.

Impact: Particles moving in straight lines fail to follow the airflow and collide with the fibers.

Interception: Particles moving with the airflow and touch the fibers and are trapped.

Diffusion: Very small particles become mobile due to random movements and collide with the filter fibers, lose their movement and remain trapped.

HEPA filters are very important in maintaining air quality in clean rooms, HVAC systems and help prevent infections and health risks due to contamination of the manufactured product.

Air exchange in clean rooms is important for preventing contamination. The higher the air exchange, the less chance of particle accumulation. Recommended air exchange in critical rooms is 20-40 times per hour.

Pressure system design:

Maintaining different pressures between rooms allows for the prevention of contaminants from the external environment passing in or from the production room to the outside

Positive pressure: Using positive pressure in clean rooms aims to prevent contaminants from entering from the outside.

Negative pressure: Using negative pressure in rooms aims to prevent the exit of harmful substances and environmental contamination.

Choosing materials and construction:

Choosing materials that are suitable for sterile conditions, smooth walls and floors prevent the accumulation of dust and dirt.

Chemical-resistant materials that withstand frequent washing and disinfection.

Sealing and drainage allow for the design of an effective drainage system and sealing to prevent contamination.

Lighting system design:

Lighting systems that ensure sufficient lighting without overheating the space LED lighting prevents overheating and provides stable lighting.

Control and Monitoring System Design

There are different types of real-time monitoring and control systems that allow real-time warning in the event of a deviation as well as documentation of production conditions throughout the production process.

Examples of common systems are:

Particle monitoring: Systems for continuous monitoring of particle levels in the air.

Temperature and humidity control: Maintaining appropriate temperature and humidity.

Pressure monitoring: Systems for monitoring air pressure in the various rooms.

Planning the flow of people and materials and residues from the process

One of the main causes of contamination in production rooms is the drag of contamination on workers or by equipment parts that are brought into the room. In order to reduce and prevent contamination as well as cross contamination, it is necessary to plan, define and control the movement of people, materials, equipment and residues from the production process. This is done, among other things, by building separate entry and exit areas (Air lock) under pressure that does not allow air to leak from an area with a low level of cleanliness to a high level of cleanliness. Entry rooms are at a cleanliness level that matches the room to which entry is required

Beneficial design is a design that prevents the entry and exit of materials and people from the same room and defines different areas for each operation

Maintenance and cleaning planning

The design and planning of the clean room should be carried out in a way that allows for effective maintenance and cleaning of the room

Accessibility to systems, easy access to HVAC systems, lighting and monitoring for maintenance.

Planning strong and efficient cleaning systems for clean rooms. Future needs should always be taken into account and efforts should be made to ensure that the design allows flexibility and adaptation to future changes.

Modular systems: Use of modular systems for future adjustments and upgrades.

Preparation rooms: Design of separate rooms for preparing materials and storing them, which can be used for changing needs.

 

Compliance with standards and regulations

Ensuring compliance with international and local standards and regulations:

ISO 14644 standards: – Design in accordance with international cleanroom standards.

GMP guidelines: Design in accordance with the Good Manufacturing Practices guidelines of the pharmaceutical industry.

Local requirements: Ensuring compliance with local regulatory requirements.

 

Classification of clean rooms according to European guidelines:

The European guidelines divide clean rooms into four main grades:

Grade A – a critical area where very important operations are carried out such as sterile filling and sealing.

Grade B – an environment surrounding the area where critical operations are carried out

Grade C & D – Workrooms and support activities as well as corridors leading to production rooms and sometimes also equipment storage areas.

ISO Guidelines

The international standard ISO 14644 classifies cleanrooms according to the number of particles of a certain size present in a cubic meter of air. The ratings range from ISO 1 to ISO 9, the requirements are based on a particle count of ≥0.1 microns per cubic meter of air.

Number of particles allowed (≥0.1 µm) Suitable industries Main requirements Class
10 Microelectronics Very small particles, intended for the production of chips and micro components. ISO 1
100 Microelectronics Advanced chip production, advanced research laboratories and development.

ISO 2
1,000 Microelectronics, Optics Manufacturing of electronic components, precision optical systems.

ISO 3
10,000 Optics and Food Manufacturing of optical components, advanced laboratories in the food industry.

ISO 4
100,000 Pharma

(Grade A), Cosmetics

Cleanrooms for sterile manufacturing processes, pharmaceutical manufacturing, cosmetic manufacturing. ISO 5
1,000,000 Pharmaceutical (Grade B) Medical product manufacturing, manufacturing areas adjacent to critical areas. ISO 6
10,000,000 Pharmaceutical (Grade C) and Food Production of less critical preparations, food packaging. ISO 7
100,000,000 Pharma (Grade D) Food Less critical production areas in the pharma, food manufacturing and packaging industries. ISO 8
Unspecified Industrial plants A level of cleanliness similar to typical outdoor air, intended for general use and plants that do not require high levels of cleanliness. ISO 9

 

Comparison of ISO requirements with European guidelines:

ISO 1 to ISO 3 are suitable for very sensitive industries such as microelectronics.

ISO 5 corresponds to Grade A in European regulations

ISO 7 corresponds to Grade C in European regulations

The comparison between European guidelines and ISO is made according to the number of particles and bacteria allowed, with ISO mainly focused on particles.

When deciding to establish a production room, all steps must be carried out from defining needs to validation. Below are the main principles and tests that must be carried out:

Defining requirements – (URS – User Requirement Specification)

Documenting needs and requirements: Identifying and documenting all needs and requirements from the clean room, including capacity, types of processes, and regulatory requirements, all according to the activity and the product produced.

In each field, experts in the specific field must be selected and held meetings to understand the technical and environmental requirements.

All requirements must be written and summarized in the URS document and before starting work, the contractor must receive final approval of the URS document from all relevant parties.

Detailed Design – (DQ – Design Qualification)

Architectural and Engineering Plan Review: Review and approval of the architectural plans, including the room structure, internal division and equipment location. Review of systems such as HVAC Review of the design of the ventilation and filtration systems, including air flow rates, filter location and air ducts. Selection of materials and testing their suitability, which includes testing construction materials to ensure they meet cleanliness and chemical resistance requirements. Approval of detailed plans, obtaining approval for all plans and designs from all relevant parties.

Construction and erection:

Material testing: Verifying that all materials comply with the URS and DQ requirements.

Construction Inspection: Monitoring construction progress and checking compliance with approved plans.

Structural Inspections: Structural inspections that include pressure, permeability, and tightness tests.

HVAC System Installation

Installation Inspections: Verifying that HVAC systems have been installed properly according to plans.

Filtration Inspections: Verifying that filters are intact and their capture capacity.

Lighting and Control System Installation

Lighting Inspections: Verifying that the lighting installation meets cleanliness and sterility requirements.

Control and Monitoring System Inspections: Verifying the functioning of control and monitoring systems, including temperature and pressure monitoring systems.

Step 4: Validation (IQ, OQ, PQ)

IQ – Installation Qualification

Equipment Compatibility Inspections: Verifying that all equipment is installed properly and meets the requirements of the technical specifications.

System Connection Inspections: Verifying all connections of HVAC, electrical, water, etc. systems.

Documentation of all equipment: Documentation of all equipment and devices, including serial numbers and labels.

OQ – Operational Qualification

HVAC system performance tests: Testing air flow rates, filter function, and air pressure.

Environmental tests: Testing temperature, humidity, and particle levels under various operating conditions.

Safety tests: Verifying that all control and safety systems are operating properly.

Equipment performance tests: Testing the performance of all equipment and devices installed in the cleanroom.

PQ – Performance Qualification

Normal operating conditions tests: Testing the cleanroom under normal operating conditions to ensure that it meets cleanliness and sterility requirements.

Periodic tests: Performing periodic tests to monitor the performance of the systems and the environment, including particle and bacteria count tests.

Stress test: Testing the performance of the systems under extreme or load conditions.

Risk Management

At each stage of the work, risk management must be implemented, ensuring that everything possible is done to prevent future risks to the safety or effectiveness of the product and emphasizing all the risk management requirements required to prevent direct or cross-contamination. These must be documented in the CCS document – ​​contamination control strategy

Risk Identification: Identifying all potential risks at each stage of the project.

Risk Assessment: Assessing the severity of risks and their likelihood.

Risk Prevention: Planning and implementing measures to prevent or reduce risks.

Monitoring and Control: Continuous monitoring and control of risks, including making corrections and improvements as necessary.

Validation and Revalidation

Initial validation includes tests and documentation that ensure that the cleanroom meets all requirements. The tests include:

Particle count measurement – ​​performed using a particle counter either fixed or portable

Bacteria levels – testing by opening plates or contact plates containing a substance that encourages the growth and vegetation of bacteria and fungi. The location of the plates is selected through risk management to ensure that normal bacteria levels are maintained throughout the work space according to the activities being carried out in it

Filtration efficiency – filter integrity

Air exchange – how many air exchanges are there per unit of time

Revalidation is performed at a regular frequency (usually once a year) or when there is a significant change in the production process or in the room structure.

 

Additional industries with cleanroom requirements

Besides the pharmaceutical industry, other industries require cleanrooms, including:

Electronics industry: manufacturing of chips and sensitive components.

Food industry: manufacturing and packaging of food.

Cosmetics industry: Production of skin and hair care products.

Principles of air filtration and laminar flow

Filtration in clean rooms is carried out using HEPA and ULPA filters, which are capable of capturing very small particles. Laminar flow ensures a unidirectional air flow, which effectively removes particles and prevents their accumulation.

Summary

Clean rooms are an essential component in the pharmaceutical and biotech industries, and play a central role in maintaining product quality and safety. Clean room requirements vary depending on use and regulations, and it is important to ensure validation and revalidation in accordance with the strictest standards. Innovations in the field of filtration and laminar flow continue to improve the ability to maintain clean rooms and ensure product quality.

x
סייען נגישות
הגדלת גופן
הקטנת גופן
גופן קריא
גווני אפור
גווני מונוכרום
איפוס צבעים
הקטנת תצוגה
הגדלת תצוגה
איפוס תצוגה

אתר מונגש

אנו רואים חשיבות עליונה בהנגשת אתר האינטרנט שלנו לאנשים עם מוגבלויות, וכך לאפשר לכלל האוכלוסיה להשתמש באתרנו בקלות ובנוחות. באתר זה בוצעו מגוון פעולות להנגשת האתר, הכוללות בין השאר התקנת רכיב נגישות ייעודי.

הסדרי נגישות

בבניין המשרדים קיימים הסדרי נגישות לבעלי מוגבלויות: בבניין בו פועלת החברה, ישנם שירותים נגישים המיועדים למבקרים עם מוגבלויות בכל קומה. כמו כן, קיימות חניות מיוחדות לנכים המגיעים למשרד ברכב ובעלי תו נכה, והן מסומנות בהתאם בחניונים הסמוכים. בנוסף, ניתן להשתמש במעליות הנגישות בבניין, והכניסות למבקרים עם מוגבלויות רחבות ומותאמות. כדי להבטיח נגישות מיטבית, נעשה שימוש בשיפוע בכניסה לבניין, המיועד לבעלי מוגבלויות וכיסאות גלגלים. כמו כן, ניתן להיכנס לבניין ולמשרדים עם חיית שירות.

סייגי נגישות

למרות מאמצנו להנגיש את כלל הדפים באתר באופן מלא, יתכן ויתגלו חלקים באתר שאינם נגישים. במידה ואינם מסוגלים לגלוש באתר באופן אופטימלי, אנה צרו איתנו קשר

רכיב נגישות

באתר זה הותקן רכיב נגישות מתקדם, מבית all internet - בניית אתרים. רכיב זה מסייע בהנגשת האתר עבור אנשים בעלי מוגבלויות.